- INSTALLATION
Joint Design: For optimum results, joints should be a minimum of 4 times
greater than anticipated movement. Minimum recommended joint size is 1/4"
x 1/4". Maximum joint size should be 1/2" width by 3/8" in depth.
Surface Preparation Priming is not required unless specified above. Joints
should be basically clean and surface dry, although dampness from dew will
not interfere with adhesion.
Do Not Use: Xylol or MEK to clean joints or to remove surface
coatings, unless surface can be allowed to dry before application of
sealant. If the joint is wet with solvent, the sealant will not adhere
properly. Use of a dry rag or brush to remove dust, dirt or other
contaminants is recommended. Contamination from curing agents and form
releases should be avoided.
Joint Backing: Joint depth should not exceed 3/8". An open cell backer
rod should be used to control joint depth. In shallow joints, a bond
breaker tape should be installed to prevent three-point contact.
Service Temperature: -40° F to 180° F
Application Temperature: -40° F to 140° F
Application and Tooling: Apply with conventional caulking
equipment, filling joint completely. When temperature is below 40 degrees
F., application will be easier if sealant is warmed. When temperature of
surface to be sealed exceeds 140° F., do not apply sealant until surface
cools. A soap solution or a solvent such as Xylol may be used as a
lubricant for tooling. Do not allow tooling agents to contaminate open
joints.
Painting: Sealant may be painted after 24 hours. If using a
relatively inflexible paint, allow sealant to cure for 3 days before
painting. Geocel 2300 may be coated with any latex and most oil-base
paints. Some paints may crack in dynamic joints. See paint manufacturers
specifications.
Cleaning: Remove Geocel 2300 from gun and tools before it cures.
This may be done by scraping and use of solvents such as MEK (lacquer
thinner), Xylol, Toluol or chlorinated solvents. Cured materials may be
removed by cutting with sharp tools. Observe manufacturer's precautions
when using toxic or flammable solvents.
- STORAGE LIFE: One year
Precautions: Apply with adequate ventilation. Avoid eye contact. As
supplied, product may be harmful or fatal if swallowed; do not induce
vomiting, contact a physician immediately. Although the solvent blend is
considered mild, some people may experience sensitivity to it.
- LIMITED WARRANTY: Geocel Corporation warrants that the product
is manufactured according to their published standards and that the
product is free from defects. The company guarantees for five years from
the date of manufacture that Geocel 2300 will not crack due to normal
expansion and contraction and that it will not lose its adhesion or
cohesion. Geocel Corporation will, at its option, either refund the
purchase price of, or provide replacement for, that portion of the Geocel
2300 which fails to perform in accordance with this warranty. Such refund
or replacement will constitute the limit of Geocel's liability and
obligation for any such failure. Geocel Corporation will not be liable or
obligated otherwise for any loss or damage, arising directly or
indirectly, from Geocel 2300 or the use or failure thereof, whether based
on breach of warranty or negligence.
- MAINTENANCE: No maintenance should be required. If the sealant
is damaged either remove bead and reseal with Geocel 2300, or apply
additional Geocel 2300 over the damaged area.
- TECHNICAL SERVICES: Geocel representatives throughout the U.S.
are available to provide technical assistance. Geocel's in house technical
staff and laboratory facilities are equipped to respond to specific
requests for further information and/or applications testing.
|
THEORETICAL YIELD
PER CARTRIDGE |
| Joint Size |
Linear Feet |
| 1/4" x 1/4" |
25.5 |
| 1/4" x 3/8" |
16.9 |
| 1/4" x 1/2" |
12.7 |
| 1/2" x 3/8" |
8.4 |
| 1/2" x 1/2" |
6.4 |
| 3/4" x 1/2" |
4.2 |
|